3. Product Introduction

3.1. Features at a Glance

The BDx Module offers a turn-key rack-mount blocking diode solution, including:

  • Fully integrated and enclosed heatsinking and fan cooling

  • User I/O status feedback including a temperature alarm state

  • Front panel status indicator

  • Heavy-duty tin-plated copper bus bars

  • Remote sensing terminal for voltage feedback compensation

  • Universal single phase active-PFC AC input connection

Internally, semiconductors are secured to Magna-Power manufactured heatsinks with fans and integrated thermocouples. An internal microprocessor monitors the internal temperature and provides +5V digital output signal when the system is powered and in a normal operating state. This +5V signal can be easily integrated into interlock systems, to ensure power is only driven through the BDx Module when its powered on and cooling is functional. Additional, a +5V digital input allows control of when the BDx Module is turned off and on, providing complete integration with a connected power supply.

A quick summary of the BDx Module key features:

  • Add-on module for MagnaDC power supplies

  • 4 models addressing broad range of applications

  • Protection up to 1,200 Vdc

  • Forward current up to 1,200 Adc

  • Fully integrated cooling with status indicator

  • Power supply user I/O controls interface

  • Included fixed rail rack-mount kit

3.2. Models

The following tables list the available models in the BDx Module.

3.2.1. Model Ordering Guide

The following ordering guide defines how an BDx Module is defined:

_images/ordering_guide_bdx.svg

Fig. 3.1 BDx Module Model Ordering Guide

3.2.2. BDx Module Models

Model

Config

Max DC Input Voltage

Max Current

Reverse Voltage Rating

Typical Losses

BDx-A1-1000-300/UI

A1

1000 Vdc

300 Adc

1200 Vdc

Up to 1.4%

BDx-A1-150-600/UI

A1

150 Vdc

600 Adc

200 Vdc

Up to 2.5%

BDx-A1-1000-600/UI

A1

1000 Vdc

600 Adc

1200 Vdc

Up to 1.4%

BDx-A1-150-1200/UI

A1

150 Vdc

1200 Adc

200 Vdc

Up to 2.5%

3.3. Specifications

3.3.1. AC Input Specifications

1Φ AC Input Voltage
1Φ, 2-wire + ground

85 to 265 Vac

AC Input Connector

IEC 60320 C13 receptacle

AC Input Frequency

50-60 Hz

AC Input Isolation

±1500 Vac, maximum input voltage to ground

3.3.2. External User I/O Specifications

External User I/O Port

15-pin D-Sub DB-15, female

Digital Output Voltage
System Status
+5V when systems normal.
0V when off or faulted state.
Connected to MagnaDC interlock input via provided cable.
Digital Input Voltage
Enable
+5V to engage cooling fans.
0V to disable product.
Connected to MagnaDC power status output via provided cable.

Remote Sense

6-32 screw connection for positive terminal

For more details about the External User I/O, see: Operation: External User I/O.

3.3.3. Physical Specifications

Racking Standard

EIA-310

Rear Support Rails

Included

Size and Weight
Configuration A1, All Models
1U
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
20 lbs (9.07 kg)

3.3.4. Environmental Specifications

Ambient Operating Temperature

0°C to 50°C

Storage Temperature

-25°C to +85°C

Humidity

Relative humidity up to 95% non-condensing

Air Flow

Side air inlet, rear exhaust

3.3.5. Regulatory Compliance

EMC

Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A

Safety

Complies with EN61010-1
Complies with 2014/35/EU (Low Voltage Directive)

CE Mark

Yes

RoHS Compliant

Yes

3.4. Dimensional Diagrams

The following are vectorized dimensional diagrams for the BDx Module. Click the respective image for a larger view. 3D STEP models can be downloaded from Magna-Power’s downloads page.

_images/diagram_bdx_3d.svg

Fig. 3.2 BDx Module dimensional diagrams

_images/diagram_bdx_3d_rear.svg

Fig. 3.3 BDx Module rear view without the protective cover (left) and with the protective cover (right)