.. _regulation-states: Regulation States ----------------- The |product_full| has three regulation states: :ref:`constant-voltage`, :ref:`constant-current`, and :ref:`constant-power`. The active regulation state is indicated by a illuminated circular LED next to the respective voltage, current, power, or resistance set-point button. The active regulation state can also be monitored programmatically. .. _constant-voltage: Constant Voltage (CV) ^^^^^^^^^^^^^^^^^^^^^ When the constant voltage regulation state is indicated, the |product_type| is maintaining fixed voltage set-point, while the current flucuates with the driving DC source, as illustrated by :numref:`fig-operating-mode-cv`. .. _fig-operating-mode-cv: .. figure:: /_common-all/_images/operating-mode-cv.* :width: 300pt :align: center Operating range in constant voltage mode .. _constant-current: Constant Current (CC) ^^^^^^^^^^^^^^^^^^^^^ When the constant current regulation state is indicated, the |product_type| is maintaining a fixed current set-point, while the voltage fluctuates with the driving DC source, as illustrated by :numref:`fig-operating-mode-cc`. .. _fig-operating-mode-cc: .. figure:: /_common-all/_images/operating-mode-cc.* :width: 300pt :align: center Operating range in constant currnet mode .. _constant-power: Constant Power (CP) ^^^^^^^^^^^^^^^^^^^ When the constant power regulation state is indicated, the |product_type| is maintaining a fixed power set-point by varying the current level inversely in response to a change in input voltage, as illustrated by :numref:`fig-operating-mode-cp`. .. _fig-operating-mode-cp: .. figure:: /_common-all/_images/operating-mode-cp.* :width: 300pt :align: center Operating range in constant power mode