Specifications

AC Input Specifications

1Φ AC Input Voltage
1Φ, 2-wire + ground
100 to 240 Vac (UI: Universal input; 1.5 kW Models)
208 to 240 Vac (UI2: Universal input; 2.6 kW Models)
3Φ AC Input Voltage
3Φ, 3-wire + ground
Available on all models
208 Vac (operating range 187 to 229 Vac)
240 Vac (operating range 216 to 264 Vac)
380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)

AC Input Current

Refer to chart of available models

AC Input Frequency

50-400 Hz

Power Factor

0.99 at max power; models with 1Φ AC input
>0.82 at max power; models with 3Φ AC input

AC Input Isolation

±2500 Vdc, maximum input voltage to ground

Output Specifications

Voltage Ripple

Refer to chart of available models.

Line Regulation

Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale

Load Regulation

Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale

Load Transient Response

2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change

Stability

± 0.10% for 8 hrs. after 30 min. warm-up

Efficiency

84% to 95%; refer to chart of available models

DC Output Isolation

±1500 Vdc max output voltage to ground

Programming Specifications

Programming Accuracy

Voltage: ±0.075% of max voltage rating
Current: ±0.075% of max current rating

Measurement Accuracy

Voltage: ±0.2% of max voltage rating
Current: ±0.2% of max current rating
Maximum Slew Rate
Standard Models
170 ms, output voltage change from 0 to 63%
200 ms, output current change from 0 to 63%
Maximum Slew Rate
Models with High Slew Rate Option (+HS)
5 ms, output voltage change from 0 to 63%
10 ms, output current change from 0 to 63%

Trip Settings Range

Over Voltage: 10% to 110% max voltage rating
Over Current: 10% to 110% max current rating

Computer Command Protocol

Standard Commands for Programmable Instruments (SCPI)

Remote Sense Limits
Wired

3% maximum voltage drop from output to load

Connectivity Specifications

Communication Interfaces (Standard)

RS232: DB-9, Female
External User I/O: DB-37, Female

Communication Interfaces (Optional)

LXI TCP/IP Ethernet: RJ-45
GPIB: IEEE-488

External User I/O Specifications

Digital Inputs

5 V, 10 kΩ impedance

Digital Monitoring Signals

5 V, 5 mA capacity

Digital Reference Signal

5 V output, 25 mA capacity

Analog Programming Input

0-10 V

Analog Programming Impedance

10 kΩ

Analog Monitoring Signals

0-10 V, 5 mA capacity

Analog Monitoring Impedance

100 Ω

Analog Monitoring Accuracy

0.2% of max rating

Analog Reference Signal

10 V, 5 mA capacity, 1 Ω impedance

For more details about the External User I/O, see: user-io.

Physical Specifications

Power Level

Rack Units

Size

Weight

1.5 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

32 lbs (14.52 kg)

2.6 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

34 lbs (15.42 kg)

4 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

35 lbs (15.88 kg)

6 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

35 lbs (15.88 kg)

8 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

36 lbs (16.33 kg)

10 kW

1U

1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)

37 lbs (16.78 kg)

Environmental Specifications

Ambient Operating Temperature

-25°C to 50°C

Storage Temperature

-40°C to +85°C

Humidity

Relative humidity up to 95% non-condensing

Air Flow

Side air inlet, rear exhaust

Temperature Coefficient

0.04%/°C of maximum output voltage
0.06%/°C of maximum output current

Regulatory Compliance

EMC

Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A

Safety

NRTL Listed, TÜV SÜD Certificate U8 123461 0001
Tested to UL 61010-1:2012/R:2019-07 and CSA C22.2 No. 61010:2012/A1:2018-11
Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive)

CE Mark

Yes

RoHS Compliant

Yes