Specifications¶
AC Input Specifications¶
1Φ AC Input Voltage
1Φ, 2-wire + ground
|
100 to 240 Vac (UI: Universal input; 1.5 kW Models)
208 to 240 Vac (UI2: Universal input; 2.6 kW Models)
|
3Φ AC Input Voltage
3Φ, 3-wire + ground
Available on all models
|
208 Vac (operating range 187 to 229 Vac)
240 Vac (operating range 216 to 264 Vac)
380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)
|
AC Input Current |
Refer to chart of available models |
AC Input Frequency |
50-400 Hz |
Power Factor |
0.99 at max power; models with 1Φ AC input
>0.82 at max power; models with 3Φ AC input
|
AC Input Isolation |
±2500 Vdc, maximum input voltage to ground |
Output Specifications¶
Voltage Ripple |
Refer to chart of available models. |
Line Regulation |
Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale
|
Load Regulation |
Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale
|
Load Transient Response |
2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Stability |
± 0.10% for 8 hrs. after 30 min. warm-up |
Efficiency |
84% to 95%; refer to chart of available models |
DC Output Isolation |
±1500 Vdc max output voltage to ground |
Programming Specifications¶
Programming Accuracy |
Voltage: ±0.075% of max voltage rating
Current: ±0.075% of max current rating
|
Measurement Accuracy |
Voltage: ±0.2% of max voltage rating
Current: ±0.2% of max current rating
|
Maximum Slew Rate
Standard Models
|
170 ms, output voltage change from 0 to 63%
200 ms, output current change from 0 to 63%
|
Maximum Slew Rate
Models with High Slew Rate Option (+HS)
|
5 ms, output voltage change from 0 to 63%
10 ms, output current change from 0 to 63%
|
Trip Settings Range |
Over Voltage: 10% to 110% max voltage rating
Over Current: 10% to 110% max current rating
|
Computer Command Protocol |
Standard Commands for Programmable Instruments (SCPI) |
Remote Sense Limits
Wired
|
3% maximum voltage drop from output to load |
Connectivity Specifications¶
Communication Interfaces (Standard) |
RS232: DB-9, Female
External User I/O: DB-37, Female
|
Communication Interfaces (Optional) |
LXI TCP/IP Ethernet: RJ-45
GPIB: IEEE-488
|
External User I/O Specifications¶
Digital Inputs |
5 V, 10 kΩ impedance |
Digital Monitoring Signals |
5 V, 5 mA capacity |
Digital Reference Signal |
5 V output, 25 mA capacity |
Analog Programming Input |
0-10 V |
Analog Programming Impedance |
10 kΩ |
Analog Monitoring Signals |
0-10 V, 5 mA capacity |
Analog Monitoring Impedance |
100 Ω |
Analog Monitoring Accuracy |
0.2% of max rating |
Analog Reference Signal |
10 V, 5 mA capacity, 1 Ω impedance |
For more details about the External User I/O, see: user-io.
Physical Specifications¶
Power Level |
Rack Units |
Size |
Weight |
---|---|---|---|
1.5 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
32 lbs (14.52 kg) |
2.6 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
34 lbs (15.42 kg) |
4 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
35 lbs (15.88 kg) |
6 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
35 lbs (15.88 kg) |
8 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
36 lbs (16.33 kg) |
10 kW |
1U |
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
|
37 lbs (16.78 kg) |
Environmental Specifications¶
Ambient Operating Temperature |
-25°C to 50°C |
Storage Temperature |
-40°C to +85°C |
Humidity |
Relative humidity up to 95% non-condensing |
Air Flow |
Side air inlet, rear exhaust |
Temperature Coefficient |
0.04%/°C of maximum output voltage
0.06%/°C of maximum output current
|
Regulatory Compliance¶
EMC |
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
|
Safety |
NRTL Listed, TÜV SÜD Certificate U8 123461 0001
Tested to UL 61010-1:2012/R:2019-07 and CSA C22.2 No. 61010:2012/A1:2018-11
Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive)
|
CE Mark |
Yes |
RoHS Compliant |
Yes |