1.5.1. Target Diagnostics
The BDx Module incorporates Target Diagnostics, a six-LED matrix on the rear panel that mirrors the status indicators located on each major internal assembly. The Target Diagnostic LEDs are readable with the unit rack-mounted and with the covers attached. Target Diagnostic LEDs correspond to the internal assemblies listed in LED Map for Target Diagnostics. Each LED flashes the Morse Code dot/dash pattern shown in LED Morse Code patterns and descriptions to report the assembly’s state (heartbeat, configuration notice, or fault).
Fig. 1.1 Target diagnostics LED matrix on the rear of the product
Letter |
Morse Code |
Description |
|---|---|---|
A |
· − |
[A]ctive control |
B |
− · · · |
[B]oot Failure |
C |
− · − · |
[C]heck Firmware |
D |
− · · |
[D]etect Master Slave |
E |
· |
[E]mpty/Corrupt External Flash |
F |
· · − · |
[F]ault |
G |
− − · |
[G]lobal Shutdown Detected |
H |
· · · · |
[H] |
I |
· · |
[I]ndependent Standalone Role |
J |
· − − − |
[J] |
K |
− · − |
[K] |
L |
· − · · |
[L]oad EEPROM |
M |
− − |
[M]aster Role |
N |
− · |
[N] Calibrate HR Capture |
O |
− − − |
C[o]mmunications Error on Firmware Upgrade |
P |
· − − · |
[P]rogramming Flash |
Q |
− − · − |
[Q] |
R |
· − · |
[R]eset Waiting for Initialization |
S |
· · · |
[S]tandby/[S]lave Role |
T |
− |
[T]arget Ready Waiting State |
U |
· · − |
[U] |
V |
· · · − |
[V] |
W |
· − − |
[W]riting Ext. Flash |
X |
− · · − |
E[x]ternal Flash read/corruption failure |
Y |
− · − − |
[Y] |
Z |
− − · · |
[Z] |