3.3. Specifications¶
3.3.1. AC Input Specifications¶
1Φ AC Input Voltage
1Φ, 2-wire + ground
|
85 to 265 Vac |
AC Input Connector |
IEC 60320 C13 receptacle |
AC Input Frequency |
50-60 Hz |
AC Input Isolation |
±1500 Vac, maximum input voltage to ground |
3.3.2. External User I/O Specifications¶
External User I/O Port |
15-pin D-Sub DB-15, female |
Digital Output Voltage
System Status
|
+5V when systems normal.
0V when off or faulted state.
Connected to MagnaDC interlock input via provided cable.
|
Digital Input Voltage
Enable
|
+5V to engage cooling fans.
0V to disable product.
Connected to MagnaDC power status output via provided cable.
|
Remote Sense |
6-32 screw connection for positive terminal |
For more details about the External User I/O, see: BDx Module D-Sub 15-pin BDx Interface user I/O connector (female) pin numbering.
3.3.3. Physical Specifications¶
Racking Standard |
EIA-310 |
Rear Support Rails |
Included |
Size and Weight
Configuration A1, All Models
|
1U
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
20 lbs (9.07 kg)
|
3.3.4. Environmental Specifications¶
Ambient Operating Temperature |
0°C to 50°C |
Storage Temperature |
-25°C to +85°C |
Humidity |
Relative humidity up to 95% non-condensing |
Air Flow |
Side air inlet, rear exhaust |
3.3.5. Regulatory Compliance¶
EMC |
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
|
Safety |
Complies with EN61010-1
Complies with 2014/35/EU (Low Voltage Directive)
|
CE Mark |
Yes |
RoHS Compliant |
Yes |