3.3. Specifications

3.3.1. AC Input Specifications

1Φ AC Input Voltage
1Φ, 2-wire + ground

85 to 265 Vac

AC Input Connector

IEC 60320 C13 receptacle

AC Input Frequency

50-60 Hz

AC Input Isolation

±1500 Vac, maximum input voltage to ground

3.3.2. External User I/O Specifications

External User I/O Port

15-pin D-Sub DB-15, female

Digital Output Voltage
System Status
+5V when systems normal.
0V when off or faulted state.
Connected to MagnaDC interlock input via provided cable.
Digital Input Voltage
Enable
+5V to engage cooling fans.
0V to disable product.
Connected to MagnaDC power status output via provided cable.

Remote Sense

6-32 screw connection for positive terminal

For more details about the External User I/O, see: BDx Module D-Sub 15-pin BDx Interface user I/O connector (female) pin numbering.

3.3.3. Physical Specifications

Racking Standard

EIA-310

Rear Support Rails

Included

Size and Weight
Configuration A1, All Models
1U
1.75” H x 19” W x 24” D
(4.4 x 48.3 x 61.0 cm)
20 lbs (9.07 kg)

3.3.4. Environmental Specifications

Ambient Operating Temperature

0°C to 50°C

Storage Temperature

-25°C to +85°C

Humidity

Relative humidity up to 95% non-condensing

Air Flow

Side air inlet, rear exhaust

3.3.5. Regulatory Compliance

EMC

Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A

Safety

Complies with EN61010-1
Complies with 2014/35/EU (Low Voltage Directive)

CE Mark

Yes

RoHS Compliant

Yes