AC Input Connection

A single-phase AC input connection is used to provide a ground reference and power for the Accessory fans and control circuits. The AC input power requirements are defined on the BDx Module product rating label. The AC input requirements are further defined in this section.

To provide AC power to the BDx Module, connect the provided power cord to the IEC 60320 C13 AC power receptacle, as shown in BDx Module IEC 60320 C13 AC power receptacle.

_images/installation-power-plug-c13.svg

BDx Module IEC 60320 C13 AC power receptacle

Warning

The power cord provides a chassis ground through the third conductor. Be certain that your power outlet is of the three-conductor type with the correct pin connected to earth ground.

Fuse Rating

The BDx Module is fused on its auxiliary power supply assembly, which is a printed circuit board (PCB) assembly located inside the product. The fuse can be accessed by removing the BDx Module top cover and locating the only PCB assembly inside.

The fuse is a through-hole component designated by F3 on the PCB. This fuse carries a 3.15 Aac rating, Bussmann / Eaton manufacturer part number SS-5H-3.15A-APH, Magna-Power Item 32060.

Failure of this fuse typically indicates a failure of this auxiliary power supply assembly and it’s recommended to contact Magna-Power support in the event this fuse has cleared.