2.5. Specifications
2.5.1. AC Input Specifications
3Φ AC Input Voltage
3Φ, 3-wire + ground
Available on all models
|
380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)
|
AC Input Current |
Refer to AC Input Current |
AC Input Frequency |
50-60 Hz |
Power Factor |
>0.92 at max power; 150 kW models
>0.96 at max power; 250 kW models
|
AC Input Isolation |
±2500 Vdc, maximum input voltage to ground |
2.5.2. Output Specifications
Voltage Ripple |
Refer to chart of available models. |
Line Regulation |
Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale
|
Load Regulation |
Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale
|
Load Transient Response |
2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Stability |
± 0.10% for 8 hrs. after 30 min. warm-up |
Efficiency |
90% to 92%; refer to chart of available models |
DC Output Isolation
Models Rated ≤1000 Vdc
|
±1000 Vdc, max output voltage to ground |
DC Output Isolation
Models Rated >1000 Vdc or
Models with +ISO Option
|
±6000 Vdc, max output voltage to ground |
2.5.3. Programming Specifications
Programming Accuracy |
Voltage: ±0.075% of max voltage rating
Current: ±0.075% of max current rating
|
Measurement Accuracy |
Voltage: ±0.2% of max voltage rating
Current: ±0.2% of max current rating
|
Maximum Slew Rate
Standard Models
|
<170 ms, output voltage change from 0 to 63%
<200 ms, output current change from 0 to 63%
|
Maximum Slew Rate
Models with High Slew Rate Option (+HS)
|
<5 ms, output voltage change from 0 to 63%
<10 ms, output current change from 0 to 63%
|
Bandwidth
Standard Models
|
3 Hz, remote analog voltage
2 Hz, remote analog current
|
Bandwidth
Models with High Slew Rate Option (+HS)
|
60 Hz, remote analog voltage
45 Hz, remote analog current
|
Trip Settings Range |
Over Voltage: 10% to 110% max voltage rating
Over Current: 10% to 110% max current rating
|
Computer Command Protocol |
Standard Commands for Programmable Instruments (SCPI) |
Remote Sense Limits
Wired; Available on Models Rated ≤1000 Vdc
without the +ISO Option
|
3% maximum voltage drop from output to load |
2.5.4. Connectivity Specifications
Communication Interfaces (Standard) |
RS232: DB-9, Female
External User I/O: DB-37, Female
|
Communication Interfaces (Optional) |
LXI TCP/IP Ethernet: RJ-45
GPIB: IEEE-488
|
2.5.5. External User I/O Specifications
Digital Inputs |
5 V, 10 kΩ impedance |
Digital Monitoring Signals |
5 V, 5 mA capacity |
Digital Reference Signal |
5 V output, 25 mA capacity |
Analog Programming Input |
0-10 V |
Analog Programming Impedance |
10 kΩ |
Analog Monitoring Signals |
0-10 V, 5 mA capacity |
Analog Monitoring Impedance |
100 Ω |
Analog Monitoring Accuracy |
0.2% of max rating |
Analog Reference Signal |
10 V, 5 mA capacity, 1 Ω impedance |
For more details about the External User I/O, see: Operation: External User I/O.
2.5.6. Physical Specifications
Power Level |
Cabinet |
Size |
Weight |
|---|---|---|---|
150 kW |
Floor-standing double-bay 19” cabinet
Qty (6) locking casters, standard
|
67” H x 48” W x 31.5” D
(170.2 x 121.9 x 80.0 cm)
|
2100 lbs (952.5 kg) |
250 kW |
Floor-standing triple-bay 19” cabinet
Qty (8) locking casters, standard
|
67” H x 72” W x 31.5” D
(170.2 x 182.9 x 80.0 cm)
|
3300 lbs (1496.9 kg) |
2.5.7. Environmental Specifications
Ambient Operating Temperature |
0°C to 50°C |
Storage Temperature |
-40°C to +85°C |
Humidity |
Relative humidity up to 95% non-condensing |
Air Cooling |
Front and rear air inlet, top exhaust |
Temperature Coefficient |
0.04%/°C of maximum output voltage
0.06%/°C of maximum output current
|
2.5.8. Regulatory Compliance
EMC |
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
|
Safety |
Complies with EN61010-1
Complies with 2014/35/EU (Low Voltage Directive)
|
CE Mark |
Yes |
RoHS Compliant |
Yes |