2.5. Specifications
2.5.1. AC Input Specifications
1Φ AC Input Voltage
1Φ, 2-wire + ground
Available on 2 kW models
|
208 Vac (208SP: operating range 187 to 229 Vac)
240 Vac (240SP: operating range 216 to 264 Vac)
|
3Φ AC Input Voltage
3Φ, 3-wire + ground
Available on all models
|
208 Vac (operating range 187 to 229 Vac)
240 Vac (operating range 216 to 264 Vac)
380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)
|
AC Input Current |
Refer to AC Input Connection |
AC Input Frequency |
50-400 Hz |
Power Factor |
>0.92 at max power; models with 3Φ AC input
0.70 at max power; models with 1Φ AC input
|
AC Input Isolation |
±2500 Vdc, maximum input voltage to ground |
2.5.2. Output Specifications
Voltage Ripple |
Refer to chart of available models. |
Line Regulation |
Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale
|
Load Regulation |
Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale
|
Load Transient Response |
2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Stability |
± 0.10% for 8 hrs. after 30 min. warm-up |
Efficiency |
80% to 93%; refer to chart of available models |
DC Output Isolation
Models Rated ≤1000 Vdc
|
±1000 Vdc, max output voltage to ground |
DC Output Isolation
Models Rated >1000 Vdc and ≤3000 Vdc
|
±(1500 Vdc + Vo/2), max output voltage to ground, where Vo is the max rated voltage |
DC Output Isolation
Models Rated >3000 Vdc
|
No output isolation, specify positive or negative output polarity at time of order |
2.5.3. Programming Specifications
Programming Accuracy |
Voltage: ±0.075% of max voltage rating
Current: ±0.075% of max current rating
|
Measurement Accuracy |
Voltage: ±0.2% of max voltage rating
Current: ±0.2% of max current rating
|
Maximum Slew Rate
Standard Models
|
< 170 ms, output voltage change from 0 to 63%
< 200 ms, output current change from 0 to 63%
|
Maximum Slew Rate
Models with High Slew Rate Option (+HS)
and Models Rated >3000 Vdc
|
< 5 ms, output voltage change from 0 to 63%
< 10 ms, output current change from 0 to 63%
|
Trip Settings Range |
Over Voltage: 10% to 110% max voltage rating
Over Current: 10% to 110% max current rating
|
Computer Command Protocol |
Standard Commands for Programmable Instruments (SCPI) |
Remote Sense Limits
Wired; Available on Models Rated ≤1000 Vdc
|
3% maximum voltage drop from output to load |
2.5.4. Connectivity Specifications
Communication Interfaces (Standard) |
RS232: DB-9, Female
External User I/O: DB-37, Female
|
Communication Interfaces (Optional) |
LXI TCP/IP Ethernet: RJ-45
GPIB: IEEE-488
|
2.5.5. External User I/O Specifications
Digital Inputs |
5 V, 10 kΩ impedance |
Digital Monitoring Signals |
5 V, 5 mA capacity |
Digital Reference Signal |
5 V output, 25 mA capacity |
Analog Programming Input |
0-10 V |
Analog Programming Impedance |
10 kΩ |
Analog Monitoring Signals |
0-10 V, 5 mA capacity |
Analog Monitoring Impedance |
100 Ω |
Analog Monitoring Accuracy |
0.2% of max rating |
Analog Reference Signal |
10 V, 5 mA capacity, 1 Ω impedance |
For more details about the External User I/O, see: External User I/O.
2.5.6. Physical Specifications
Racking Standard |
EIA-310 |
Rear Support Rails |
Included |
Power Level |
Rack Units |
Size |
Weight |
|---|---|---|---|
2 kW |
2U |
3.50” H x 19” W x 24” D
(8.89 x 48.26 x 60.96 cm)
|
45 lbs (20.41 kg) |
4 kW |
2U |
3.50” H x 19” W x 24” D
(8.89 x 48.26 x 60.96 cm)
|
47 lbs (21.32 kg) |
6 kW |
2U |
3.50” H x 19” W x 24” D
(8.89 x 48.26 x 60.96 cm)
|
48 lbs (21.77 kg) |
8 kW |
2U |
3.50” H x 19” W x 24” D
(8.89 x 48.26 x 60.96 cm)
|
48 lbs (21.77 kg) |
10 kW |
2U |
3.50” H x 19” W x 24” D
(8.89 x 48.26 x 60.96 cm)
|
48 lbs (21.77 kg) |
2.5.7. Environmental Specifications
Ambient Operating Temperature |
-25°C to 50°C |
Storage Temperature |
-40°C to +85°C |
Humidity |
Relative humidity up to 95% non-condensing |
Air Flow |
Side air inlet, rear exhaust |
Temperature Coefficient |
0.04%/°C of maximum output voltage
0.06%/°C of maximum output current
|
2.5.8. Regulatory Compliance
EMC |
Complies with European EMC Directive for test and measurement products, 2014/30/EU |
Safety |
Complies with EN61010-1:2010 |
CE Mark |
Yes |
RoHS Compliant |
Yes |