Accessory Product

BDx Module

1U blocking diode module add-on with fully integrated cooling

The BDx Module provides a fully integrated 1U rack-mount blocking diode solution for high-power DC power supply applications, including necessary cooling, status monitoring, and digital I/O for monitoring. With high-current ratings and communications integration with MagnaDC power supplies, the BDx Module provides a turn-key solution for battery charging, capacitor charging, and protection from back-EMF from motor drives.

Key Features

  • Add-on module for MagnaDC power supplies
  • 4 ratings, each in three configurations
  • Protection up to 1,200 Vdc
  • Forward current up to 1,200 Adc
  • Fully integrated cooling with status indicator
  • Power supply user I/O controls interface
  • Included fixed rail rack-mount kit
Magna-Power Expert

Talk with an expert

•
•

Applications

Back EMF Protection

Prevent back electromotive force (EMF) from electric motors, or current from connected charged batteries and capacitors, from flowing back into the power supply's output.

High Voltage Protection

Protect the power supply and other DC power equipment from externally generated DC bus voltages that could exceed the equipment's maximum ratings.

Mixed Voltage Paralleling

Connect multiple power supplies with different voltage ratings in parallel, while protecting the lower voltage products from high bus voltages.

Prevent Load Discharge

Prevent the power supply's internal bleeder network from discharging batteries, capacitors, or fuel cells when the power supply is in standby, in a faulted state, or turned off.

Self-Contained Rack-Mount Solution

The Integrated Blocking Diode (+BD) option builds the blocking diode into the power supply itself. For applications or products where the +BD option is not available or desired, the BDx Module provides blocking diode protection as a self-contained 1U rack-mount module, including:

  • Enclosed heatsinking and fan cooling
  • User I/O status feedback, including a temperature alarm state
  • Front panel status indicator
  • Heavy-duty tin-plated copper bus bars
  • Remote sensing terminal for voltage feedback compensation
  • Universal single-phase active-PFC AC input connection

How It Works

Internally, the semiconductors are secured to Magna-Power manufactured heatsinks with fans and integrated thermocouples. An internal microprocessor monitors the internal temperature and provides a +5 V digital output signal when the BDx Module is powered and in a normal operating state.

Interlock integration: the +5 V status signal integrates easily into interlock systems, so power is only driven through the BDx Module when it is powered on and its cooling is functional. On A1 and B1 models, the provided interface cable connects the status signal to the MagnaDC power supply's interlock input.

On/off control: a +5 V digital input controls when the BDx Module turns on and off, for complete integration with a connected power supply.

Master/slave systems: the BDx Module connects directly to the breakout connector of the UID53 Universal Interface Device, preserving its full protection features, including power supply shutdown on a module thermal alarm, inside a master/slave system.

Choose Your Configuration

Every BDx Module rating is available in three configurations. They share the same electrical ratings and differ in the interface cable supplied for connecting the BDx Module to a power supply.

Configuration A1: SL, XR, TS, MT, and ML Series

A1 models include an interface cable for SL, XR, TS, MT, and ML Series MagnaDC power supplies. The cable connects the BDx Module's status output to the power supply's interlock input, so power only flows through the BDx Module while it is powered on and its cooling is working.

Configuration B1: SLx Series

B1 models include an interface cable for SLx Series MagnaDC power supplies, making the same status and interlock connection.

Configuration C1: No Interface Cable

C1 models ship without an interface cable, for customers who integrate the BDx Module into their own application, use it with other power supplies, or use it in other applications. These customers wire the BDx Module's external user I/O connector to suit their system, in accordance with the BDx Module user manual.

Models

Each rating is available in all three configurations:

ModelConfigMax DC Input VoltageMax CurrentReverse Voltage RatingTypical LossesInterface CablePriceOrder
BDx-A1-150-600/UIA1150 Vdc600 Adc200 VdcUp to 2.5%SL, XR, TS, MT, and ML Series
BDx-B1-150-600/UIB1150 Vdc600 Adc200 VdcUp to 2.5%SLx Series
BDx-C1-150-600/UIC1150 Vdc600 Adc200 VdcUp to 2.5%NoneContact for Quote
BDx-A1-150-1200/UIA1150 Vdc1,200 Adc200 VdcUp to 2.5%SL, XR, TS, MT, and ML Series
BDx-B1-150-1200/UIB1150 Vdc1,200 Adc200 VdcUp to 2.5%SLx SeriesContact for Quote
BDx-C1-150-1200/UIC1150 Vdc1,200 Adc200 VdcUp to 2.5%NoneContact for Quote
BDx-A1-1000-300/UIA11,000 Vdc300 Adc1,200 VdcUp to 1.4%SL, XR, TS, MT, and ML Series
BDx-B1-1000-300/UIB11,000 Vdc300 Adc1,200 VdcUp to 1.4%SLx Series
BDx-C1-1000-300/UIC11,000 Vdc300 Adc1,200 VdcUp to 1.4%NoneContact for Quote
BDx-A1-1000-600/UIA11,000 Vdc600 Adc1,200 VdcUp to 1.4%SL, XR, TS, MT, and ML Series
BDx-B1-1000-600/UIB11,000 Vdc600 Adc1,200 VdcUp to 1.4%SLx SeriesContact for Quote
BDx-C1-1000-600/UIC11,000 Vdc600 Adc1,200 VdcUp to 1.4%NoneContact for Quote

Model Ordering Guide

BDx Module models are defined by the configuration type and number, the maximum DC input voltage rating, and the maximum current rating.

Specifications are subject to change without notice. Unless otherwise noted, all specifications measured at the product's maximum ratings.

AC Input Specifications

1Φ AC Input Voltage
1Φ, 2-wire + ground
85 to 265 Vac
AC Input Connector
IEC 60320 C13 receptacle
AC Input Frequency
50-60 Hz
AC Input Isolation
±1500 Vac, maximum input voltage to ground

External User I/O Specifications

External User I/O Port
15-pin D-sub DB-25, female
See User Manual for pin layout
Digital Output Voltage
System Status
+5V when systems normal.
0V when off or faulted state.
A1 and B1: connected to the MagnaDC interlock input via the provided interface cable.
Remote Sense
6-32 screw connection for positive terminal

Physical Specifications

Racking Standard
EIA-310
Rear Support Rails
Included
Size and Weight
Configuration A1, All Models
1U
1.75” H x 19” W x 24” D (4.4 x 48.3 x 61.0 cm)
20 lbs (9.07 kg)

Environmental Specifications

Ambient Operating Temperature
0°C to 50°C
Storage Temperature
-40°C to +85°C
Humidity
Relative humidity up to 95% non-condensing

Regulatory Compliance

EMC
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
Safety
Complies with EN61010-1
Complies with 2014/35/EU (Low Voltage Directive)
CE Mark
Yes
RoHS Compliant
Yes

Documentation

BDx Module User Manual [0.018] [EN] [PDF]