2.3. Specifications

2.3.1. AC Input Specifications

Input Voltages Available
Refer to models table for AC input voltage availability by power level AC Input voltage specified at time of order and cannot be modified
UI, 100-240 Vac, 1-phase
UI2, 208-240 Vac, 1-phase
208 Vac, 3-phase
240 Vac, 3-phase
380/400 Vac, 3-phase
415 Vac, 3-phase
440 Vac, 3-phase
480 Vac 3-phase

Input Voltage Tolerance

± 10%

Input Voltage Frequency

50-400 Hz

Power Factor
Measured at max power
> 0.99, 1-phase UI and UI2 AC inputs
> 0.92, 3-phase AC inputs
Input Isolation
Measured line-to-ground

± 2000 Vdc

2.3.2. DC Output Specifications

Voltage Ripple

Model specific. Refer to models table.

Line Regulation

Voltage control: ± 0.04% of rated voltage
Current control: ± 0.03% of rated current
Power control: ± 0.05% of rated power

Load Regulation

Voltage control: ± 0.02% of rated voltage
Current control: ± 0.06% of rated current
Power control: ± 0.08% of rated power
Stability
FWHM, measured at 25ºC over 8 hrs after 30 min warm-up
Voltage control: ± 0.005% of rated voltage
Current control: ± 0.075% of rated current

Temperature Coefficient

Voltage control: 0.01%/ºC of rated voltage
Current control: 0.04%/ºC of rated current
Power control: 0.04%/ºC of rated power

Efficiency

Up to 95%. Model specific. Refer to Models table.

Slew Rate, Voltage
Standard models, programmable
Minimum (Slowest): Rated voltage x 2-15 [V/ms]
Maximum (Fastest): Rated voltage x 0.006 [V/ms]
Slew Rate, Current
Standard models, programmable
Minimum (Slowest): Rated current x 2-15 [A/ms]
Maximum (Fastest): Rated current x 0.005 [A/ms]
Slew Rate, Power
Standard models, programmable

Minimum (Slowest): Rated power x 2-15 [W/ms] | Maximum (Fastest): Rated power x 0.0025 [W/ms]

Output Isolation
Measured output-to-ground

± 2000 Vdc

2.3.3. Programming Specifications

Resolution, Digital Programming
Front panel or communication interfaces

16-bit, 0.00153% of rated voltage, current or power

Accuracy, Digital Programming
Output value to set point value, programmed via front panel or communication interfaces
Voltage: ± 0.06% of rated voltage
Current: ± 0.06% of rated current
Power: ± 0.10% of rated power
Accuracy, Digital Measurement
Output value to returned value, via front panel display or communication interfaces
Voltage: ± 0.08% of rated voltage
Current: ± 0.08% of rated current
Power: ± 0.10% of rated power
Resolution, Analog Programming
0-10 V analog input

12-bit, 0.025% of rated voltage, current or power

Accuracy, Analog Programming
Output value to set point value, programmed via analog input
Voltage: ± 0.12% of rated voltage
Current: ± 0.08% of rated current
Power: ± 0.10% of rated power
Accuracy, Analog Programming, High Speed Input
Output value to set point value, programmed via the high-speed analog input
Voltage: ± 0.80% of rated voltage
Current: ± 0.80% of rated current
Power: ± 1.20% of rated power
Accuracy, Analog Measurement
Output value to returned value, via analog output
Voltage: ± 0.08% of rated voltage
Current: ± 0.08% of rated current
Power: ± 0.10% of rated power
Analog I/O
3 configurable standard analog inputs, 1 configurable high-speed analog input, reference signal provided
High-Speed Input Sampling Rate: 2 kHz
Programming Voltage: 0-10 V
Monitoring Voltage: 0-10 V, 3 mA capacity
Monitoring Impedance: 0.005 Ω
Reference Voltage: 10 V, 20 mA capacity

2.3.4. Interface Specifications

Front Panel Programming

Machined aluminum rotary knob with encoder, keypad, and up-down arrow for single bit control

Communication Interfaces
Standard
USB Host (Front): Type B
USB Host (Rear): Type B
RS485 (Rear): RJ-45
MagnaLINK™: RJ-25 x 2
External User I/O Port
Standard
26-pin D-sub DB-26, female
Referenced to ground; isolated from the DC output
See User Manual for pin layout
Communication Interfaces
Optional
CANopen (+CAN): RJ-45 x 2
EtherCAT (+ECAT): RJ-45 x 2
EtherNet/IP (+EIP): RJ-45 x 2
LXI TCP/IP Ethernet (+LXI): RJ-45
ModbusTCP (+MTCP): RJ-45 x 2
PROFINET (+PROF): RJ-45 x 2

2.3.5. Physical Specifications

Size
All models
1U
1.75” H x 19” W x 24” D (4.4 x 48.3 x 61.0 cm)

Weight

1.5 kW models: 32 lbs (14.52 kg)
2.6 kW models: 34 lbs (15.42 kg)
4 kW models: 35 lbs (15.88 kg)
6 kW models: 35 lbs (15.88 kg)
8 kW models: 36 lbs (16.33 kg)
10 kW models: 36 lbs (16.33 kg)

Racking Standard

EIA-310

Rear Support Rails

Included

2.3.6. Environmental Specifications

Ambient Operating Temperature

0°C to 50°C

Storage Temperature

-35°C to +85°C

Humidity

Relative humidity up to 95% non-condensing

Air Flow

Side air inlet, rear exhaust

2.3.7. Regulatory Specifications

EMC

Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A

Safety

Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive)

CE Mark

Yes

RoHS Compliant

Yes

REACH Compliant

Yes