Knowledge Base

计算稳压输出阻抗

MagnaDC电源具有稳压输出。稳压电压模式输出阻抗可使用公式1计算,而稳压电流模式阻抗可使用公式2计算。此稳压输出阻抗不同于输出端的泄放电阻,泄放电阻在电源处于待机状态或关闭时存在于电路中。

`V_(text(imp))=V_(reg)*(V_(text(rating))/I_(text(rating)))`
(1)
`I_(text(imp))=V_(text(rating))/(I_(text(rating))*I_(reg))`
(2)

其中 `V_(reg)` 为电压模式负载调整率,`I_(reg)` 为电流模式负载调整率,`V_(text(rating))` 为电源的满量程电压额定值,`I_(text(rating))` 为电源的满量程电流额定值。

例如,以型号SL50-80/208为例。该型号的 `V_(text(rating))` 为50 Vdc,`I_(text(rating))` 为80 Adc,根据规格参数,`V_(reg)` 为0.01%,`I_(reg)` 为0.04%。公式3给出了该型号在电压模式控制下的计算输出阻抗。公式4给出了该型号在电流模式控制下的计算输出阻抗。

`V_(text(imp))=0.0001*(50/80)`
(3)
`V_(text(imp))=6.25*10^-5" [Ω]"`
`I_(text(imp))=50/(80*0.0004)`
(4)
`I_(text(imp))=1563" [Ω]"`
Originally published 二月 8, 2018

Stay connected and informed.

Subscribe to receive emails—no more than once per month—with new technical articles, product releases and factory updates from Magna-Power.

Have any questions or feedback?
We'd love to hear from you.
Contact us