输出泄放电阻
MagnaDC电源的输出由大量电容器组成,用于滤除输出纹波。与这些电容器并联的是一个电阻式泄放电路,用于在电源不使用时将电容器放电至安全水平。泄放电路对产品的电压和电流测量是透明的。由于电源的输出在产品的输出端子处进行调节,因此当电源输出启用时,泄放器不在电路中。当电源处于待机状态或关闭时,泄放电路将对直流母线施加负载。如果不希望电流放电至电源输出端,阻断二极管将防止例如连接到直流母线的电池或电容器在电源待机或关闭时向电源输出端泄放。
泄放电阻的大小因功率等级和型号的峰值输出电压额定值而异。高电压或高功率产品使用额定为机组峰值电压的无源电阻,而中低电压产品使用恒功率电子泄放器,在所有电压水平下提供近乎相等的负载。表1提供了MagnaDC机架式产品的集成泄放电阻。表2提供了MagnaDC落地式产品的集成泄放电阻。
Table 1. Output bleed resistance for SL Series MagnaDC programmable power supplies.
| Power Level | 1.5 kW to 8 kW | 1.5 kW to 8 kW |
| Max Output Voltage Rating | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc |
| Bleeder Resistance | 50 watts | 25 watts |
| Constant Power | No | Yes |
Table 2. Output bleed resistance for XR Series MagnaDC programmable power supplies.
| Power Level | 2 kW to 10 kW | 2 kW to 10 kW |
| Max Output Voltage Rating | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc |
| Bleeder Resistance | 50 watts | 25 watts |
| Constant Power | No | Yes |
Table 3. Output bleed resistance for TS Series MagnaDC programmable power supplies.
| Power Level | 5 kW to 15 kW | 5 kW to 15 kW | 20 kW and 25 kW | 20 kW and 25 kW | 20 kW and 25 kW | 20 kW and 25 kW | 30 kW | 30 kW | 40 kW | 40 kW | 50 kW | 50 kW |
| AC Input Voltage | All | All | 208/240 Vac | 208/240 Vac | 380/415 Vac or 440/480 Vac | 380/415 Vac or 440/480 Vac | All | All | All | All | All | All |
| Max Output Voltage Rating | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc |
| Bleeder Resistance | 50 watts | 25 watts | 100 watts | 50 watts | 50 watts | 25 watts | 100 watts | 50 watts | 100 watts | 50 watts | 100 watts | 50 watts |
| Constant Power | No | Yes | No | Yes | No | Yes | No | Yes | No | Yes | No | Yes |
Table 4. Output bleed resistance for MS Series MagnaDC programmable power supplies.
| Power Level | 30 kW | 30 kW | 45 kW | 45 kW | 60 kW | 60 kW | 75 kW | 75 kW |
| Max Output Voltage Rating | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc | < 16 Vdc or > 1000 Vdc | ≥ 16 Vdc or ≤ 1000 Vdc |
Bleeder Resistance | 100 watts | 50 watts | 150 watts | 75 watts | 200 watts | 100 watts | 250 watts | 125 watts |
| Constant Power | No | Yes | No | Yes | No | Yes | No | Yes |
Table 5. Output bleed resistance for MT Series MagnaDC programmable power supplies.
| Power Level | 100 kW to 250 kW |
Max Output Voltage Rating | All |
Bleeder Resistance | 500 watts |
| Constant Power | No |
Originally published 二月 8, 2018