附件产品

Universal Interface Device

高性能即插即用主从控制

通用接口设备47(UID47)旨在大幅简化MagnaDC可编程直流电源的主从配置过程。该设备包含配置Magna-Power直流电源所需的D-Sub通信电缆、连接器及电路,支持主从并联或串联运行。主从并联运行允许两台或多台电源连接后均等分配输出电流。主从串联运行允许两台或多台电源连接后均等分配输出电压。

UID47上额外的37针扩展连接器直接与主电源对应,使主从系统仍可通过模拟-数字用户I/O进行控制和监测。UID47还在印刷电路板上预留了用于互连导线和放置特定用户应用组件的区域,可连接至10针用户扩展连接器。

SKU 描述 价格 数量
UID46 UID46
UID47 UID47
UID53 UID47
Magna-Power 专家

与专家交谈

Add-On - Accessory - Universal Interface Device 图片

Choose Your UID

One UID is required for every slave power supply in the system.

UID46 — Analog Reference Control

[IMAGE: diagram_uid46_enclosure.eps]

The UID46 drives slave units through their 0-10 V external analog references, using the master's own monitor signals as the set point source. This method tightly matches output sharing between units, making the UID46 the recommended choice for current mode control applications and for high-current systems — such as large electromagnet and superconducting magnet loads — where current imbalance between units must be minimized. In current mode control, transient response is identical to the UID47 and UID53.

Includes: UID46, qty (2) 6-ft 37-conductor shielded cables
[ADD TO CART — UID46]

UID47 — Gate Driver Control

[IMAGE: diagram_uid47_enclosure.eps]

The UID47 configures the master power supply to directly control the gate drivers of its slave units. With a single control loop commanding every unit, the UID47 delivers the fastest transient response performance, making it the general-purpose choice for most master/slave systems.

Includes: UID47, qty (2) 6-ft 37-conductor shielded cables
[ADD TO CART — UID47]

UID53 — Gate Driver Control + BDx/DBx Module Breakout

[IMAGE: diagram_uid53_enclosure.eps]

The UID53 provides everything in the UID47, plus a dedicated 37-pin breakout connector (JR5) that carries the power supply interface signals required by Magna-Power's BDx and DBx Modules. In a master/slave system the power supply's user I/O connector is occupied by the UID cable — the UID53's breakout and included 37-pin to 15-pin interface cable let a BDx or DBx Module integrate with the power supply while it remains part of the master/slave configuration.

Includes: UID53, qty (2) 6-ft 37-conductor shielded cables, 37-pin to 15-pin module interface cable
[ADD TO CART — UID53]

Model Comparison

 UID46UID47UID53
Master/slave control methodAnalog reference programming (0-10 V)Direct gate driver controlDirect gate driver control
Transient responseSame as UID47/UID53 in current mode control; slower in voltage mode controlFast, single control loopFast, single control loop
Parallel current sharingTightly matched between unitsTotal current as programmed; division between units may vary up to 5% of full scaleTotal current as programmed; division between units may vary up to 5% of full scale
BDx/DBx Module breakoutYes
Custom user circuitry pad areaYesYesYes
Best suited forCurrent mode control applications or high current systems where current imbalance between units must be minimizedGeneral purpose master/slave operationMaster/slave systems integrating a BDx or DBx Module

In every configuration, the total output of the system matches the programmed value; a two-unit parallel system delivers twice the current programmed on the master. The comparison above describes only how that total divides between units.


 

Parallel operation connects two or more power supplies for a total output current equal to the sum of the individual units, with equal current sharing under all load conditions and complete control from the master.

Series operation connects two or more power supplies for a total output voltage equal to the sum of the individual units, with equal voltage sharing under all load conditions.

Systems scale to three or more supplies by daisy-chaining additional UID units, so master control and monitoring signals route automatically to every slave. Each UID ships factory-configured for parallel operation; switching to series requires only moving the internal jumper.

BDx/DBx Module integration (UID53): blocking diode and high-stability modules connect directly to the UID53's breakout connector, preserving full module protection features, including power supply shutdown on module thermal alarm, inside a master/slave system.

Internal PCB layout for UID46/47 showing pad areas for custom circuitry.
Internal PCB layout for UID46/47 showing pad areas for custom circuitry.

Every UID doubles as a development platform for custom control and monitoring. All 37 power supply interface signals are broken out to labeled pad areas on the printed circuit board, a 10-position screw-terminal connector provides user-defined external connections, and a general-purpose prototyping area in the center of the board accepts user components, for example, OR'ing diodes to combine multiple diagnostic alarm signals into a single output.

规格如有变更,恕不另行通知。除非另有说明,所有规格均在产品的最大额定值下测量。

Connectivity Specifications

Slave connector (JR1)
DB-37, female
Master connectors (JR2, JR3)
DB-37, female; JR3 daisy-chains additional UID units
User connector (JR4)
10-position screw terminal plug
Breakout connector (JR5, UID53 only)
DB-37; BDx/DBx Module interface via included 37-pin to 15-pin cable
Power requirements
None (passive device)

Physical Specifications

Size
1.21″ H × 7.14″ W × 4.01″ D (3.07 × 18.14 × 10.19 cm)
Weight
0.5 lbs (0.23 kg)

Environmental Specifications

Ambient operating temperature
-25°C to +50°C
Storage temperature
-40 °C to +85 °C